Own workshop · Over 25 years in Mallorca

Car Park Ventilation in Mallorca

For residents' associations, managing agents and commercial car parks. If you have received a notice, send it over and we will tell you what is actually required.

Steel · Fibreglass · Spiral · Stainless Fixed written quote within 48 hours

25

Years in the trade

5

Fitters on the team

48

Hours to your quote

100

% Mallorca

What we do

We fabricate the ductwork in our own workshop and install it ourselves, island-wide.

🌬

Ducted air conditioning

Cooling throughout the property with no units on show. We make the ductwork to measure and install it.

🧱

Fibreglass ductwork

The usual duct for interior residential work. Factory insulated, light, and it absorbs air noise.

🔩

Galvanised steel ductwork

Tougher, for outdoors, roofs and exposed runs. Insulated with a wrap and foil so it does not condense.

Spiral ductwork

Round steel duct, for exposed runs in warehouses and commercial units or where a lot of air has to move.

🛡

Stainless steel ductwork

For kitchen extraction and seafront properties. AISI 304 and 316, made to measure in our own workshop.

🍳

Kitchen extraction

Canopies, stainless ductwork, make-up air and roof discharge. For restaurants, bars and hotels.

💨

Ventilation and fresh air

Extract and supply air for warehouses, car parks, shops and offices. Sized for how the space is actually used.

🏭

Fabricación a medida

Cortamos y plegamos en nuestro taller antes de pisar la obra. Y servimos a instaladoras a precio de industrial.

🚗

Ventilación de garajes

Para comunidades y administradores de fincas. Si tiene un requerimiento, se lo miramos antes de presupuestar.

Work we have done

Red de chapa, fibra en falso techo, helicoidal visto y extracción de cocina.

Climaver fibreglass duct installed above the ceiling with brackets Finished ductwork in a home before the ceiling goes up Indoor unit connected to the ductwork through a fibreglass plenum Fibreglass duct with a bend suspended from the slab on site

Why this comes up

Car park ventilation does not worry anyone until a letter arrives. An inspection, an insurer's review, a change of use, building works, or simply a resident complaining about fumes.

From then on the building has a deadline and no idea where to start. And it is awkward, because someone has to explain to thirty owners why money must be spent on something nobody can see.

The first thing we do is look at exactly what is being required. A forced ventilation requirement, a carbon monoxide detection requirement and a smoke control requirement are three different things, with three different solutions and very different costs.

And we tell you what is NOT needed. That matters just as much: we have seen buildings quoting for complete installations when the notice could be satisfied with considerably less.

How it is solved in practice

The ductwork. In a car park it is nearly always exposed spiral duct: it moves a lot of air with little pressure loss, takes the pressure without reinforcement and needs no boxing in. In a car park that is exactly what is wanted.

Airflow is calculated, not copied. It depends on spaces, floor area, headroom and whether there are one or several levels. An undersized or oversized fan costs money every month of the year and still fails to comply.

The discharge. That is where paperwork gets complicated, because it has to reach the roof or a facade at the right height and distance, and that affects neighbours. It is planned from the start, not once the duct is up.

Working with the car park in use. Nobody can leave thirty cars without parking for a week. We work by zones and phases, to a calendar agreed before starting, and we give it to you in writing so the building can approve it.

The documentation. On completion you get a record of what is installed and the measured airflows. That is what you will have to show when they ask again.

If you are a managing agent

We know how this works: you need a clear quote, defensible at a residents' meeting, that does not move afterwards.

Written quote within 48 hours, with metres, materials, timescale and phases. What we sign is what you pay.

We will attend the meeting if it helps, to explain the reason for each item. It is easier to approve what is understood.

And if you manage several buildings, say so. We organise so that the works do not all land on you in the same month.

¿Tienes una obra? Te llamamos hoy.

Déjanos tus datos y te llamamos para concertar la visita. Medimos y en 48 horas tienes el presupuesto por escrito.

Submitting opens WhatsApp. You accept our legal notice and privacy policy.

O si lo prefieres, escríbenos por WhatsApp

In short: Conductos Mallorca installs forced ventilation for car parks and garages across Mallorca, for residents' associations, managing agents and commercial car parks. The work starts by identifying exactly what the notice received requires, since a forced ventilation requirement, a carbon monoxide detection requirement and a smoke control requirement lead to different solutions and very different costs. The ductwork is normally exposed spiral duct, which moves a large volume of air with little pressure loss and needs no concealment. Airflow is calculated from the number of spaces, floor area, headroom and number of levels, and the discharge to roof or facade is planned from the outset because it affects neighbours. Work is carried out by zones and phases to an agreed calendar so the car park stays in use, and is handed over with a record of the installation and measured airflows. Fixed written quote within 48 hours. Telephone: 631 651 622.

Frequently asked questions

We have been served a notice about the car park ventilation. What first?

Send us the notice before requesting quotes. The solution changes a great deal depending on what is being required, and the first thing is to know exactly what must be complied with and what need not.

Does the car park have to close during the works?

Not entirely. We work by zones and phases, to a calendar agreed before starting, so spaces always remain available. We give it to you in writing so you can take it to the meeting.

How much does it cost to ventilate a car park?

It depends on spaces, floor area, headroom and where the air can discharge. That is why we do not quote over the phone: we come, measure and within 48 hours you have the fixed written quote.

Do you provide documentation on completion?

Yes. A record of what is installed and the measured airflows. That is what you will need to show if you are asked again.

We are a small building. Is the job worth your while?

Yes. We work with buildings of any size and also with commercial and hotel car parks. Call us and we will look at it.

About us

Conductos Mallorca fabricates and installs ductwork for air conditioning, ventilation and extraction across the island.

Experience

Over 25 years fabricating and installing ductwork in Mallorca: steel, fibreglass, spiral and stainless.

Our own team

Five fitters on the team. We do not subcontract: the person who quotes the job is the person who fits it.

Own workshop

Ductwork is fabricated before we set foot on site. Fewer days working inside and far less dust.

Fixed quote

In writing within 48 hours of the survey, with the metres, the materials and the timescale. What we sign is what you pay.

Conductos Mallorca · Tel. 631 651 622 · Servicio en toda Mallorca (Illes Balears) · Legal notice

We cover the whole island

Palma, the coastal resort areas and every other municipality on the island.

All of Mallorca Palma Calvià Andratx Llucmajor Marratxí Alcúdia Pollença Manacor Santanyí Sóller Capdepera Son Servera Sant Llorenç des Cardassar Felanitx Campos Muro Artà See all 53 municipalities
📞 Call · 631 651 622Free survey · quote in 48 h 💬